ADAPTERS, CABLES and APPLICATIONS
 

#HP-TI-PRGUSB:
Hyperion TITAN  USB/SERIAL 4-Pin Adapter Cable

Applications:

1) All TITAN MOTOR CONTROLLERS (ESC)
2) Emeter v1 and RDU*
3) EOS 06xxi CHARGERS to PC Port for:
     *EOS0610i NET and DUO - Firmware upgrades and PC Software
     *EOS0606i DC and AC/DC - EOS INSIGHT PC Software


USING the TI-PRGUSB ADAPTER :
TITAN ESC
* Whenever connecting the PRGUSB Adapter, be sure that GRD/V+/Tx/Rx orientation is correct.
* For TITAN ESC, note that the "blanked" pin on the adapter connector is always next to GRD
*The Adapter supplies power to the TITAN ESC, so a battery pack must NOT be connected to the TITAN ESC during programming.


EMETER v1
*
HP-TI-PRGUSB cannot be connected directly to EMETER v1. You must first insert the adapter for Emeter, which is included with every USB TI-PRGUSB. (pictured above, at bottom right of photo)
*For EMETER v1, note that you MUST turn Emeter ON first, then connect TI-PRGUSB to Emeter, when using Emeter PC Data Software.

(otherwise, you will see a "low battery" warning from Emeter...)

 
RDU (Remote Data Unit) uses HP-TI-PRGUSB alone (no adapter harness is needed)

EOS CHARGERS
                                           
*
HP-TI-PRGUSB cannot be connected directly to EOS Chargers. A wiring harness/extension is needed between the charger and USB Adapter:

#HP-EOS
06-PCCBL harness for PC Logging and Firmware Update:
EOS0610i-NET
EOS0610i-DUO
EOS0720i-NET
EOS0610i-DUO2

#HP-EOS
0606-PCCBL harness for PC Logging Only
EOS0606i-AD (ac/dc, all versions)
EOS0606i (dc, all versions)

Note that only the hardware v3 Series EOS Chargers (0720i-NET3, DUO3, etc) do NOT need the TI-PRGUSB adapter, nor harness. They have  built-in USB and cable.  They do, however, need the same driver.


Click here for
HP-TI-PRGUSB Driver Download and Instructions

 
#HP-AT-PRGUSB:
Hyperion TITAN  USB/SERIAL 3-Pin Adapter Cable

Applications:
1) All ATLAS Digital Servos*
2) Future devices

Click here for USB Driver Download and Instructions



 
#HP-PCCABLE:  (DISCONTINUED PRODUCT)
Hyperion TITAN  SERIAL 4-Pin Adapter Cable, connected to a PC Serial Port. A Battery Pack of 6 to 10 cells NiMH (or 2S~3S li-po) must be connected to the TITAN ESC Main Input (Red/Black) wires during ESC programming, when using Serial HP-PCCABLE, no matter with or without a USB adapter attached between PCCABLE and PC.

HP-PCCABLE is Serial, so no driver is required.  PC must have a free 9-pin serial port, and have the port enabled in CMOS setup.

Applications:
1) All TITAN MOTOR CONTROLLERS (ESC)
2) Emeter v1



Connectivity Notes:
* HP-PCCABLE (serial) is NOT a simple cable.  It contains needed conversion chip for raw to TTL serial, and the chip is a special low-draw type to reduce load on Emeter battery.

* If you have HP-PCCABLE (serial) and want to use it on a PC which has no SERIAL Port, you will need a standard USB-to-Serial adapter, such as #HP-EM-USBADAP, pictured on right.

*If you have Emeter v1, you can use simple cable #HP-EM-TITANCABLE to program TITAN ESC directly from Emeter, without Personal Computer.

* Emeter II will program TITAN ESC Servos directly from Emeter II, with the cable supplied in the box.

* Emeter II will program ATLAS Servos directly from Emeter, without intermediate cable (or use plain servo extension cable, as needed)