HYPERION DATASHEETS AND MANUALS

HYPERION SOFTWARE & FIRMWARE FILES

(updated May 18 2016)

FOR EOS0840i CHARGER  

  • Download the "EOS PC Tool" Software here
  • Download the Android APP here
  • Download the iOS APP here

FOR EOS CHARGERS  

May 11 2015: EOS Charger Firmware v5.94 is released. It replaces Li-ION mode with HVLI, for 3.8V/cell High Voltage Lithium packs, like the new Hyperion G6 Series:

Click here for EOS FIRMWARE UPDATE FILES and INFORMATION

EOS CONTROL & DATA SUITE (ECDS)  
for Windows PC (released July 2013)

Compatible with these chargers only:
EOS0720I-NET (aka NET2, requires option USB adapter)
EOS0610I-DUO2 (requires option USB adapter)
EOS0720i-NET3
EOS0615i-DUO3
EOS0720I-NET3-AD (ac/dc)
EOS0615i-DUO3+
EOS1420I-NET3
EOS0720I-SDUO3
EOS0730I-NET3

Under Win8+, ECDS may require running in Win7 or XP Compatibility Mode

EOS CONTROL & DATA SUITE Software Download

Please be sure to read the ECDS manual, especially the Quick Start Guide

This version ECDS requires EOS firmware version 5.9 or higher. Visit the EOS Firmware Update Page

ECDS Enables:
* Full Control of the Charger Via PC
* Editing/Storage/Uploading of Memory Positions to/from Charger
* Rich Data Logging features
* "Tagging" of packs for long-term analysis
* Customizable Alarms
* And more.....

FOR EMETER II (and RDU, mRDU, LDU)  

Emeter II & RDU PC Suite Software for Windows PC

Emeter II PC SUITE Software Download (v2.2.4108.14878, APR 1 2011)

Latest Firmware for Emeter II & RDU

ATLAS DIGITAL SERVO COMMANDER for WIN PC  

[for use with HP-AT-PRGUSB (usb adapter)]

Note that Emeter II can also program ATLAS Servos

TITAN ESC PROGRAMMING for WIN PC (legacy product)  

[for use with HP-TI-PRGUSB (usb) or HP-PCCABLE (serial)]

Instructions (does not include v31 revisions)

If you get a "file not found" or "xxx.file Not registered" error when trying to run any of these applications on Windows Vista, you may need to download this batch file in order to properly register some system files. Unzip it, right click, and choose RUN.

ADAPTERS, CABLES AND APPLICATIONS

#HP-TI-PRGUSB:

Hyperion TITAN USB/SERIAL 4-Pin Adapter Cable  

Applications:

  1. All TITAN MOTOR CONTROLLERS (ESC)
  2. Emeter v1 and RDU*
  3. EOS 06xxi CHARGERS to PC Port for:
    • *EOS0610i NET and DUO - Firmware upgrades and PC Software
    • *EOS0606i DC and AC/DC - EOS INSIGHT PC Software

USING the TI-PRGUSB ADAPTER :

TITAN ESC  

  • * Whenever connecting the PRGUSB Adapter, be sure that GRD/V+/Tx/Rx orientation is correct.
  • * For TITAN ESC, note that the "blanked" pin on the adapter connector is always next to GRD
  • *The Adapter supplies power to the TITAN ESC, so a battery pack must NOT be connected to the TITAN ESC during programming.

EMETER v1  

  • *HP-TI-PRGUSB cannot be connected directly to EMETER v1. You must first insert the adapter for Emeter, which is included with every USB TI-PRGUSB. (pictured above, at bottom right of photo)
  • *For EMETER v1, note that you MUST turn Emeter ON first, then connect TI-PRGUSB to Emeter, when using Emeter PC Data Software.
    (otherwise, you will see a "low battery" warning from Emeter...)

RDU (Remote Data Unit) uses HP-TI-PRGUSB alone (no adapter harness is needed)

EOS CHARGERS  

  • *HP-TI-PRGUSB cannot be connected directly to EOS Chargers. A wiring harness/extension is needed between the charger and USB Adapter:

RDU (Remote Data Unit) uses HP-TI-PRGUSB alone (no adapter harness is needed)

#HP-EOS06-PCCBL harness for PC Logging and Firmware Update:  

  • EOS0610i-NET
  • EOS0610i-DUO
  • EOS0720i-NET
  • EOS0610i-DUO2

#HP-EOS0606-PCCBL harness for PC Logging Only  

  • EOS0606i-AD (ac/dc, all versions)
  • EOS0606i (dc, all versions)

Note that only the hardware v3 Series EOS Chargers (0720i-NET3, DUO3, etc) do NOT need the TI-PRGUSB adapter, nor harness. They have built-in USB and cable. They do, however, need the same driver.

Click here for HP-TI-PRGUSB Driver Download and Instructions

#HP-AT-PRGUSB:

Hyperion TITAN USB/SERIAL 3-Pin Adapter Cable  

Applications:

  1. All ATLAS Digital Servos*
  2. Future devices

Click here for USB Driver Download and Instructions

 

#HP-PCCABLE: (DISCONTINUED PRODUCT)  

Hyperion TITAN SERIAL 4-Pin Adapter Cable, connected to a PC Serial Port. A Battery Pack of 6 to 10 cells NiMH (or 2S~3S li-po) must be connected to the TITAN ESC Main Input (Red/Black) wires during ESC programming, when using Serial HP-PCCABLE, no matter with or without a USB adapter attached between PCCABLE and PC.

HP-PCCABLE is Serial, so no driver is required. PC must have a free 9-pin serial port, and have the port enabled in CMOS setup.

Applications:

  1. All TITAN MOTOR CONTROLLERS (ESC)
  2. Emeter v1

Connectivity Notes:

  • * HP-PCCABLE (serial) is NOT a simple cable. It contains needed conversion chip for raw to TTL serial, and the chip is a special low-draw type to reduce load on Emeter battery.
  • * If you have HP-PCCABLE (serial) and want to use it on a PC which has no SERIAL Port, you will need a standard USB-to-Serial adapter, such as #HP-EM-USBADAP, pictured on above.
  • *If you have Emeter v1, you can use simple cable #HP-EM-TITANCABLE to program TITAN ESC directly from Emeter, without Personal Computer.
  • * Emeter II will program TITAN ESC Servos directly from Emeter II, with the cable supplied in the box.
  • * Emeter II will program ATLAS Servos directly from Emeter, without intermediate cable (or use plain servo extension cable, as needed)

All rights reserved Hyperion HK Ltd., 2005~2009

Hyperion Vengeance 2.0

Factory Default Settings: Download Here

To restore to factory default settings, you will need CleanFlight v.1.2.3.

Factory Default Settings: Download CleanFlight 1.2.3

To Install CleanFlight 1.2.3:

  1. Unzip the file you downloaded
  2. Open Chrome
  3. Point to "Customize and control Google Chrome"
  4. Click More Tools and then Extensions
  5. Tick Developer Mode
  6. Click "Load Unpacked Extensions and point to the folder where you unzip CleanFlight 1.2.3